2. Connect the common point ground cord to the table mat by snapping it to the left or right snap.
3. Connect the coil cord to the common point ground cord by plugging the banana plug into one of the ground cord's banana jacks.
4. Snap the wrist band to the coil cord. Tip: Make sure that the operator wears the wrist band on bare skin and tightens the band so that no gap exists between the skin and the band.
5. Lay the floor mat on the floor in front of the workbench with the snaps toward the bench.
6. Connect the floor mat ground cord to one snap on the floor mat.
7. Connect the common point ground cord and floor mat ground cord to ground. Use the green wire building ground point as specified in EOS/ESD Standard 6. Connection to this ground point most easily accomplished by removing the center AC outlet plate cover screw, placing the screw through the eyelets from both ground cords, and replacing the screw. The wires can be moved to the left and right sides of the screw so that they do not obstruct the outlet.